Why Does My Circuit Breaker Keep Tripping?

A circuit breaker keeps tripping because the circuit is carrying more current than its wire is rated for, or because current is leaking or arcing where it should not. When it trips is the best clue: instantly points to a short or ground fault, after a few minutes points to an overload, and at random points to an arc fault, a bad appliance or a worn breaker.

The breaker is not being fussy. It is protecting the wire inside your wall. Your job is to work out which of five causes you have, fix the easy ones yourself, and know when to stop resetting it.

When Does It Trip? Match the Pattern to the Cause

It trips…Most likely causeWhat to do
The instant you reset it, with everything unpluggedShort circuit or ground fault in the wiringLeave it off and call an electrician
As soon as you plug in or switch on one thingShort or ground fault in that appliance or its cordUnplug it, reset, and see if it holds
After a few minutes of heavy useOverload: too many watts on one circuitMove a big load to another circuit
At random, on a breaker marked AFCI or arc faultArc fault (AFCI breaker)Check cords and plugs on that circuit
In rain, or when something gets wetGround fault (GFCI breaker or outlet)Dry it out, check outdoor outlets and covers
Under light load, or the breaker is warm or buzzingWorn breaker or loose connectionStop resetting it and call

Overloaded Circuit: Trips After a Few Minutes

A 15 amp circuit at 120 volts is rated for 1,800 watts. A 20 amp circuit is rated for 2,400. For anything that runs three hours or more, the National Electrical Code limits the load to 80% of that: 12 amps on a 15 amp circuit, 16 amps on a 20 amp circuit.

That is less than people expect. A space heater labeled 1,500 watts draws 12.5 amps by itself. Add a hair dryer on the same bedroom circuit and the breaker is doing exactly what it should. Overloads trip after a delay, from seconds to several minutes, because the breaker reacts to heat building up.

Find the wattage on each device’s label, then check the circuit below.

Is this circuit overloaded?Add the watts from the labels of everything on the circuit.

Assumes 120 volts. Wattage is printed on the label or nameplate. Amps times 120 gives watts if only amps are listed.

If the numbers say overload, the fix is to spread the load: move the heater or the microwave to an outlet on a different breaker. If you run out of circuits, the answer is a new dedicated circuit, not a bigger breaker. A power strip does not add capacity either; our guide on plugging a mini fridge into a power strip explains why.

Short Circuit: Trips Instantly

A short happens when the hot wire touches the neutral wire or another hot. Current spikes with almost nothing to slow it down, and the breaker opens in a fraction of a second, often with a pop. You may find a scorch mark on an outlet, a melted plug or a burnt smell.

If the breaker trips the moment you reset it with every device unplugged, the short is in the wiring, a box or a device in the wall. That is not a homeowner fix.

Ground Fault: Kitchens, Baths and Outdoors

A ground fault is current escaping to ground, sometimes through water and sometimes through a person. GFCI outlets and breakers watch for it and cut power when the current going out and coming back differ by as little as 0.006 amps, according to the CPSC. That is why a GFCI in a bathroom, kitchen, garage or outdoor outlet trips after a rain or when an old appliance is plugged in.

The CPSC says to test each GFCI at least once a month with its test button. If it will not reset, or will not trip when tested, it needs to be replaced.

Arc Fault (AFCI) Trips

AFCI breakers, marked AFCI or “arc fault” and fitted with a test button, protect bedroom and living area circuits in newer homes. They look for the erratic current of an electrical arc. The CPSC lists the usual sources: damaged or worn cords, wire insulation punctured by a picture nail or a cable staple, cords pinched in a door or under furniture, furniture pushed against a plug, poorly installed outlets or switches, and wiring damaged by heat or sun.

Normal arcing, such as flipping a switch or pulling a plug, is not supposed to trip an AFCI. If one trips again and again, unplug everything on the circuit, inspect the cords, and add devices back one at a time. If it still trips with nothing plugged in, the problem is in the wall.

When the Breaker Itself Is the Problem

Breakers are mechanical, and they wear out. One that trips under a light load, feels warm, buzzes, or will not latch when you reset it should be replaced. Some older panels have a worse problem: breakers that fail to trip at all. Federal Pacific Stab-Lok breakers are the best-known example, covered in our guide on Federal Pacific panels.

What to Do When a Breaker Keeps Tripping

Residential breaker panel with each circuit labeled by room
A labeled panel tells you which rooms share a breaker. If yours is blank or wrong, fix the labels while you work through these steps.
  1. Turn off or unplug everything on the circuit

    Check every room. One breaker can feed outlets in two or three rooms.

  2. Reset it all the way

    A tripped breaker usually rests between ON and OFF. Push it firmly to OFF, then back to ON.

  3. Watch what happens

    If it trips again with nothing connected, stop. That is a wiring fault.

  4. Add loads back one at a time

    The device that trips it is your suspect. Try it on another circuit to confirm.

  5. Spread the load or call

    Move heavy loads to other circuits. If the pattern does not fit an overload, have the circuit tested.

Do not put in a bigger breakerA 15 amp breaker protects 14-gauge wire. A 20 amp breaker on that wire lets it run hot inside the wall before anything trips. In 1983 the CPSC put it simply: investigate why a breaker tripped, “do not simply replace the fuse or reset the breaker.”
Burning smell, scorch marks or a hot panel?Leave the breaker off, keep people away from the panel, and get help today. Our emergency electrician page explains what to do while you wait.

For trips that come back no matter what you unplug, electrical repair starts with finding the fault. A service call to diagnose it typically runs about $60 to $150 in this area, and the repair is priced in writing before any work starts.

Questions About a Breaker That Keeps Tripping

Is it dangerous to keep resetting a tripping breaker?

Resetting once is fine. If it trips again right away, stop. Each reset pushes current into a circuit that may have a short, a ground fault or an overheating connection, and the CPSC advises finding out why a breaker tripped instead of simply resetting it.

Can I replace a 15 amp breaker with a 20 amp breaker?

No. The breaker size is set by the wire. A 15 amp breaker protects 14-gauge wire, and a 20 amp breaker on that wire lets it overheat before tripping. If you need more capacity, add a new circuit sized for the load.

Can a circuit breaker go bad?

Yes. Breakers wear with age and repeated trips, and a worn one can trip below its rating or fail to trip at all. A breaker that is warm, buzzes or will not latch should be replaced by an electrician.

Why does my GFCI outlet trip when it rains?

Water in an outdoor outlet, a cover that does not seal, or a wet extension cord lets current leak to ground. A GFCI trips when that leak reaches about 0.006 amps. Dry everything out, and replace damaged covers or cords.

How much does it cost to fix a breaker that keeps tripping?

Finding the fault usually starts with a service call of about $60 to $150 in the San Angelo area. The repair depends on the cause: moving loads costs nothing, while a new breaker, outlet or circuit is priced after the diagnosis.